CPCB 4+ Generator in sushant-lok-gurgaon

CPCB 4 stands for Central Pollution Control Board (CPCB) Level 4 standards for generators. These standards are related to the emissions and environmental impact of generators used in sushant-lok-gurgaon .

CPCB sets in sushant-lok-gurgaon guidelines and standards for various industries and equipment to regulate pollution levels and ensure environmental protection. For generators, these standards specify the maximum allowable levels of pollutants like particulate matter, nitrogen oxides (NOx), sulfur dioxide (SO2), carbon monoxide (CO), and other emissions.

Generators that comply with CPCB 4 standards are designed to be more environmentally friendly and produce fewer harmful emissions compared to generators that do not meet these standards.

If you're looking to purchase or rent a generator in sushant-lok-gurgaon , it's advisable to inquire about its CPCB compliance level. This information will help ensure that the generator meets the required environmental standards and is in compliance with local regulations. Additionally, using a CPCB-compliant generator demonstrates a commitment to environmental sustainability and responsible business practices

 

Technical Data
Generator Set Specification

Prime Power Rating KVA / KW 7.5/6 10/8 12.5/10 15/12 20/16
Current ( Amps) Single / Three 31/11 41/14 51/16 62/21 82/28
Power Factor 0.8 ( Lag) 0.8 ( Lag) 0.8 (lag) 0.8 (lag) 0.8 (lag)
Nos. Of Phase 3 Phase/ 1 Phase 3 Phase/ 1 Phase 3 Phase/ 1 Phase 3 Phase/ 1 Phase 3 Phase/1 Phase


Engine Specification
Make Mahindra Mahindra Mahindra Mahindra Mahindra
Model 1125GM 2185GM 2205GM 3255GM 3305GM
BHP 11 18 20 25 30
Nos. of Cylinders 1 2 2 3 3
Cooling Water Cooled Water Cooled Water Cooled Water Cooled Water Cooled
Aspiration Natural Natural Natural Natural Natural
RPM 1500 1500 1500 1500 1500
Bore X Stroke (mm) 88.9 X110 88.9 X110 88.9X110 88.9X101.6 88.9X110
Displacement (CC) 1365 1365 1365 1895 2048
Fuel HSD HSD HSD HSD HSD
Fuel Cons. @ 75 % Load (ltr) 1.72 2.5 2.56 3.35 3.87
Governing A 2 A 1 A1 A1 A1
Starting System 12 V Electrical 12 V Electrical 12 V Electrical 12 V Electrical 12 V Electrical
Lub. Oil Sump Capacity (ltr.) 3.5 6 6 7 7
Total Coolant Capacity (ltr) 7 9.5 9.5 11 11


Alternator Specification
Make Crompton/ Stamford Crompton/ Stamford Crompton/ Stamford Crompton/ Stamford Crompton/ Stamford
Voltage Regulation +/- 1% +/- 1% +/- 1% +/- 1% +/- 1%
Class Of Insulation H Class H Class H Class H Class H Class
RPM/Frequency 1500/50 1500/50 1500/50 1500/50 1500/50


Acoustic Enclosure
Length (mm) 1800 1800 2150 2150 2150
Width (mm) 900 900 1030 1030 1030
Height (mm) 1170 1170 1250 1250 1400