A DG Set with a capacity of 82 kVA to 125 kVA refers to a Diesel Generator Set in panipat that can provide electrical power output ranging from 82 kilovolt-amperes (kVA) to 125 kVA. These generator sets are larger and more powerful than the 7.5 kVA DG Set mentioned earlier. Here are some key points to consider regarding DG Sets in this capacity range:
Capacity Range: DG Sets in the 82 kVA to 125 kVA in panipat range are considered medium-sized generators. The specific capacity within this range may vary based on the generator's model and manufacturer.
Real Power Output: The actual usable power output of these generators (measured in kilowatts, kW) may vary depending on the power factor of the connected load. The power factor accounts for the ratio of real power to apparent power.
Applications: Medium-sized DG Sets in this capacity range are suitable for a wide range of applications, including:
Providing backup power to commercial and industrial facilities.
Supporting critical infrastructure such as hospitals, data centers, and manufacturing plants.
Supplying power to construction sites and remote locations.
Backup power for medium-sized residential buildings, hotels, and small businesses.
Fuel Type: Like smaller DG Sets, generators in this range typically run on diesel fuel. Diesel generators are known for their reliability and ability to provide continuous power for extended periods.
Maintenance: Regular maintenance is crucial to ensure the reliable operation of these generators. Maintenance tasks may include oil changes, filter replacements, inspections, and load testing.
Sizing: It's essential to select a DG Set with a capacity that matches or slightly exceeds the power requirements of the connected load. An appropriately sized generator ensures that it can handle the load without being overloaded or underutilized.
Safety and Compliance: Proper installation, ventilation, safety measures, and compliance with local regulations are essential when using generators in this capacity range.
Environmental Considerations: Diesel generators produce exhaust emissions, so it's important to comply with environmental regulations and consider emissions control measures.
Manufacturer and Model: The choice of manufacturer and specific model can affect the performance, reliability, and features of the DG Set. Consider reputable manufacturers and models with a track record of reliability and serviceability.
Automatic Transfer Switch (ATS): Many larger DG Sets are equipped with ATS systems that can automatically switch the electrical load to the generator in the event of a power outage and then back to the mains when power is restored.
Before purchasing and installing a DG Set in the 82 kVA to 125 kVA range in panipat , it's advisable to consult with a qualified electrical engineer or generator expert to assess your specific power requirements and ensure that the generator is suitable for your intended applications. Additionally, local regulations and codes may dictate certain requirements for the installation and operation of diesel generators in this capacity range.
Technical Data
Generator Set Specification
Prime Power Rating KVA / KW | 82.5/66 | 100/80 | 125/100 |
Current ( Amps) | 115 | 139 | 174 |
Power Factor | 0.8 (lag) | 0.8 ( Lag) | 0.8 (lag) |
Nos. Of Phase | 3 Phase | 3 Phase | 3 Phase |
Make | Mahindra/SDEC | Mahindra | Mahindra |
Model | 41225GC | 61375GM | 61695GM |
BHP | 122 | 137 | 169 |
Nos. of Cylinders | 4 | 6 | 6 |
Cooling | Water Cooled | Water Cooled | Water Cooled |
Aspiration | Turbo | Turbo AC | Turbo AC |
RPM | 1500 | 1500 | 1500 |
Bore X Stroke (mm) | 114X130 | 96X135 | 96 X 135 |
Displacement (CC) | 5300 | 5860 | 5860 |
Fuel | HSD | HSD | HSD |
Fuel Cons. @ 75 % Load (ltr) | 14.6 | ||
Governing | Electronic | A 1 | A1 |
Starting System | 24 V Electrical | 12 V Electrical | 12 V Electrical |
Lub. Oil Sump Capacity (ltr.) | 15 | 18.5 | 18.5 |
Total Coolant Capacity (ltr) | 24.5 | 16.6 | 16.6 |
Make | Crompton/ Stamford | Crompton/ Stamford | Crompton/ Stamford |
Voltage Regulation | +/- 1% | +/- 1% | +/- 1% |
Class Of Insulation | H Class | H Class | H Class |
RPM/Frequency | 1500/50 | 1500/50 | 1500/50 |
Length (mm) | 2800 | 4000 | 4000 |
Width (mm) | 1150 | 1200 | 1200 |
Height (mm) | 1450 | 1640 | 1640 |
DG Set Weight ( Kg) | 1800 | 2500 | 2600 |
© 11 years Member dagar Gen Sets . All rights reserved | Design by Get It .info