As of my last knowledge update in September 2021, Mahindra Powerol offers a range of generators that comply with CPCB (Central Pollution Control Board) standards. The CPCB standards are set by the Indian government to regulate and control emissions from various sources, including generators in gurgaon .
The "CPCB 4+" likely refers to a specific compliance level within the CPCB standards. In this context, "CPCB 4+" would mean that the generator meets or exceeds the requirements of CPCB Level 4 standards, indicating that it is designed to produce lower emissions and have a reduced environmental impact.
If you are considering purchasing a Mahindra CPCB 4+ generator in gurgaon , I recommend contacting Mahindra Powerol directly or visiting their official website for the most up-to-date information on their generator models and their compliance with CPCB standards. Keep in mind that product specifications and compliance levels may evolve over time, so it's important to get the latest information from the manufacturer.
Technical Data
Generator Set Specification
|
||||||||||||||||||||||||
Make | Mahindra | Mahindra | Mahindra | Mahindra | Mahindra |
Model | 1125GM | 2185GM | 2205GM | 3255GM | 3305GM |
BHP | 11 | 18 | 20 | 25 | 30 |
Nos. of Cylinders | 1 | 2 | 2 | 3 | 3 |
Cooling | Water Cooled | Water Cooled | Water Cooled | Water Cooled | Water Cooled |
Aspiration | Natural | Natural | Natural | Natural | Natural |
RPM | 1500 | 1500 | 1500 | 1500 | 1500 |
Bore X Stroke (mm) | 88.9 X110 | 88.9 X110 | 88.9X110 | 88.9X101.6 | 88.9X110 |
Displacement (CC) | 1365 | 1365 | 1365 | 1895 | 2048 |
Fuel | HSD | HSD | HSD | HSD | HSD |
Fuel Cons. @ 75 % Load (ltr) | 1.72 | 2.5 | 2.56 | 3.35 | 3.87 |
Governing | A 2 | A 1 | A1 | A1 | A1 |
Starting System | 12 V Electrical | 12 V Electrical | 12 V Electrical | 12 V Electrical | 12 V Electrical |
Lub. Oil Sump Capacity (ltr.) | 3.5 | 6 | 6 | 7 | 7 |
Total Coolant Capacity (ltr) | 7 | 9.5 | 9.5 | 11 | 11 |
Make | Crompton/ Stamford | Crompton/ Stamford | Crompton/ Stamford | Crompton/ Stamford | Crompton/ Stamford |
Voltage Regulation | +/- 1% | +/- 1% | +/- 1% | +/- 1% | +/- 1% |
Class Of Insulation | H Class | H Class | H Class | H Class | H Class |
RPM/Frequency | 1500/50 | 1500/50 | 1500/50 | 1500/50 | 1500/50 |
Length (mm) | 1800 | 1800 | 2150 | 2150 | 2150 |
Width (mm) | 900 | 900 | 1030 | 1030 | 1030 |
Height (mm) | 1170 | 1170 | 1250 | 1250 | 1400 |
© 11 years Member dagar Gen Sets . All rights reserved | Design by Get It .info